{{ 'fb_in_app_browser_popup.desc' | translate }} {{ 'fb_in_app_browser_popup.copy_link' | translate }}

{{ 'in_app_browser_popup.desc' | translate }}

MENU CART {{currentCart.getItemCount()}}
Milwaukee MW802 PRO 3-in-1 pH, EC, TDS Combo Meter with ATC

Milwaukee MW802 PRO 3-in-1 pH, EC, TDS Combo Meter with ATC

Free Shipping (West Malaysia) Above RM200 on order

RM1,590.00
Quantity Product set quantity
Add to Wishlist
The maximum quantity per submit is 99999
This quantity is invalid, please enter a valid quantity.
Sold Out

Not enough stock.
Your item was not added to your cart.

Not enough stock.
Please adjust your quantity.

{{'products.quick_cart.out_of_number_hint'| translate}}

{{'product.preorder_limit.hint'| translate}}

Limit {{ product.max_order_quantity }} per order.

Only {{ quantityOfStock }} item(s) left.

Please message the shop owner for order details.
Add to Wishlist

Description

Milwaukee MW802 PRO 3-in-1 pH, EC, TDS Combo Meter – Precision & Convenience in Water Analysis

 

The Milwaukee MW802 PRO 3-in-1 Combo Meter is the ultimate solution for measuring pH, Electrical Conductivity (EC), and Total Dissolved Solids (TDS) with a single, highly efficient device. Engineered with precision and designed for maximum convenience, this portable meter is an essential tool for professionals across various industries. Whether you’re managing the delicate balance of hydroponic systems, aquaculture, or food production, the MW802 PRO provides fast, reliable results.

 

Its advanced features, such as Automatic Temperature Compensation (ATC), ensure accurate measurements in any environment, whether in the lab, field, or production site. Hydroponic growers and aquaponics enthusiasts rely on it for real-time monitoring of nutrient solutions, helping them achieve optimal plant health and yields. Greenhouses and agricultural sectors use it to fine-tune soil and water conditions, promoting healthy crop growth while maintaining cost-effective resources.

 

In aquaculture, the MW802 PRO plays a crucial role in monitoring water quality for aquatic life, ensuring ideal conditions for fish farms or aquarium setups. With its versatility, it also serves environmental scientists and water treatment specialists in analyzing water quality in natural bodies or treatment plants.In food production, manufacturers can use it to monitor processes requiring precise water conditions.

 

From research laboratories to industrial water treatment facilities, the MW802 PRO is a trusted ally in measuring pH, EC, and TDS levels, providing confidence in the integrity of the water and solutions critical to each industry. The MW802is a must-have tool for professionals who demand precision and efficiency in their water analysis.

 

Why Choose the Milwaukee MW802 PRO?

 

§  3-in-1 Functionality: Measures pH, EC, and TDS with one meter and a single probe.

§  Automatic Temperature Compensation (ATC):Ensures accuracy in all environments.

§  Simple Calibration: Single-point manual calibration for both pH and EC.

§  Rugged & Reliable: Durable design with are place able SE600 probe for long-term use.

§  Light weight & Portable: Weighs just 5.8 ounces and fits comfortably in hand.

§  Large, High-Contrast Display: View measurements quickly with an easy-to-read digital screen.

 

 

Howto Use the MW802 PRO

 

Calibrate with standard buffer solutions
Calibration is a crucial step in ensuring that the MW802 provides accurate readings. To begin, you’ll need to use standard calibration solutions with known pH, EC, and TDS values. These solutions will help set the meter to give precise readings for your specific measurements. Calibration should be performed regularly, especially if the meter is used frequently or exposed to harsh conditions. It's a good practice to calibrate before each testing session to guarantee the most accurate results.

 

Submerge the probe in the water or nutrient solution
After calibration, place the meter’s probe into the sample you intend to test,whether it’s water, nutrient solution, or soil mixture. Make sure the probe is fully submerged in the sample for consistent measurements. For nutrient solutions or water, ensure that the probe is immersed deep enough to measure the entire solution, allowing for accurate EC, pH, and TDS readings.

 

Gently stir for an accurate reading
Gently stir the probe within the sample to ensure the meter gets an even,stable reading. Stirring helps to distribute any inconsistencies in the solution, such as localized differences in pH or nutrient concentration,ensuring that the reading you get is representative of the entire sample.Stirring should be done slowly and carefully to avoid damaging the probe or disrupting the sample too much.

 

Adjust pH and nutrient levels as needed
Based on the readings provided by the MW802, you may need to adjust the pH, EC,or TDS levels of your solution. If, for example, the pH is too high or too low,you can add pH up or pH down solutions to bring it into the desired range. For EC or TDS adjustments, add the appropriate nutrient solution to ensure that plants receive the necessary levels of minerals and nutrients.

 

Clean and store the probe properly for longevity
After each use, clean the probe thoroughly to avoid the buildup of dirt, salts,or other contaminants. Proper cleaning ensures that the probe remains accurate and prevents it from becoming clogged, which could affect its readings. Once cleaned, store the probe in an appropriate solution (such as a buffer or storage solution) to keep it hydrated and prevent any damage. Avoid storing it in just water, as this can lead to contamination and shorten the lifespan of the probe.

 

Proper Meter Care & Maintenance

 

Essential Tips for Long-Lasting Performance:

 

•Store the probe properly in buffer or storage solution (MA9015, not water)
Storing the probe in a buffer or storage solution ensures it remains moist and calibrated, extending the lifespan of the probe. Never store it in pure water,as it can cause the probe to dry out, leading to inaccurate readings and damage over time. Buffer solutions are designed to maintain the probe’s calibration and functionality.

 

•Clean regularly by soaking in pH and EC cleaning solution (MA9016)
Over time, the probe can accumulate deposits from samples such as salts, oils, or other contaminants. To keep the probe in optimal condition, regularly clean it by soaking in a cleaning solution specifically designed for pH and EC probes,such as the MA9016. This ensures that any buildup is effectively removed,helping maintain the meter’s performance and accuracy.

 

•Calibrate after cleaning and before testing to maintain accuracy
After cleaning the probe, always recalibrate the MW802 before using it for measurements. Cleaning can alter the probe’s accuracy, and calibration ensures thatit provides reliable readings. Calibration should be done with fresh standard buffer solutions to restore the meter to its optimal performance.

 

•Gently stir the probe in the sample for the most reliable results
When measuring, it’s essential to stir the probe gently in the sample to obtain the most accurate and consistent readings. Stirring helps to evenly distribute any variations within the solution, ensuring that the measurement reflects the overall conditions. Avoid vigorous shaking, which could disrupt the measurement processor damage the probe.

By following these detailed instructions for use and maintenance, you’ll ensure that your MW802 PRO remains accurate, reliable, and in excellent condition,giving you the best results for your water or nutrient solution analysis overtime.

 

Order the Milwaukee MW802 PRO Today!

Whether you're managing a hydroponic system, ensuring optimal water quality in aquariums, or monitoring nutrient levels in agriculture, the Milwaukee MW802PRO 3-in-1 Combo Meter is the versatile tool you can rely on for precise pH,EC, and TDS measurements. With its easy-to-use design and accurate results, theMW802 is perfect for professionals and enthusiasts alike, helping you maintain ideal conditions for plant growth, aquatic life, and more.

 

Specifications

 

§  pH Range: 0.00 to 14.00 pH

§  EC Range: 0.00 to 6.00 mS/cm

§  TDS Range: 0 to 4000 ppm

§  pH Resolution: 0.1 pH

§  EC Resolution: 0.01 mS/cm

§  TDS Resolution: 10 ppm

§  pH Accuracy: ±0.20

§  EC/TDS Accuracy: ±2% Full Scale

§  Calibration Solutions: M10007 (pH7.01) M10032 (1382 ppm) M10442B 1500 ppm

§  Conversion Factor: 0.68

§  Calibration: Manual at 1 point

§  Temperature Compensation:Automatic from 0 to 50°C

§  Probe: SE600 combination pH/EC/TDS probe

§  Environment: 0 to 50°C / 32 to122°F; max RH 95%

§  Battery Type / Battery Life: 1 x9V alkaline / 150 hours of use

§  Auto-off: After 8 minutes of non-use

§  Dimensions: 7.3 x 3.2 x 1.8inches

§  Weight: 5.8 ounces (with battery)

 


You might also like...